G.x series master and slave equipment FAQ

“Can the G.x series coax equipment work on 50ohm and 75ohm coax cables? What would the difference in performance be between them of at all?”, “What is the Maximum I can combine on a single G.x series coax before performance is impacted?”, ” Is it possible to provide the G.x series equipment unbranded?”

G.x solution equipment projects case 1: Ethernet + CATV

  A global CATV operator customers sharing their phone line projects details:
  “We have 17 units in a building with coax. We will need the master and slave equipment please.
And we have 50 units in a building with door phones (phone line). Can you please quote on both the single ethernet port and two ethernet port slaves?
  Note: no WiFi required we will use other CPEs for that.”

Solution and equipment needed:

  1. For 17users coax network, can use 1pc G.x-M204 4output coax master (as each output can connect max 16users), and G.x-S211 with 1 ethernet +1 CATV.
    In the coax salve, you can keep the CATV port free , if you don’t need it.
  2. For 50users phone line network, can use 2pcs 24ouput G.x-M124 (each output connect to one user) and G.x-S111 with 1 ethernet port.

Question (Q): How would I handle say a hotel floor with 17 or more terminal on a single coax?

Answer (A):
  Each output port in master can connect 16terminals, if you have 17 or more, you can use two or more output ports in master.

  Coax master output port –>1:16 splitter–> coax slave.

Preview of FOT G.x series master management system

Preview of FOT G.x series master management system

Q: Can the coax equipment work on 50ohm and 75ohm coax cables? What would the difference in performance be between them of at all?
A: Our equipment is 75ohm, so if cable is 75ohm, the performance is best. If you use 50ohm, performance is not so good.

Q: Also is it possible to provide the G.x series equipment unbranded?
A: If the master Qty>10pcs, slave >200pcs, we can make it unbrand.

ModelDescription
G.x-M204G.hn coax master:
Data input: 2*GE SFP slots
Monitor Port: 1*GE SFP slot
CATV Input Port: 4 RF ports
Output: 4 CATV/G.hn RF ports
Console port: RS232 (RJ45)
G.x-M208G.hn coax master:
Data input: 2*GE SFP slots
Monitor Port: 1*GE SFP slot
CATV Input Port: 8 RF ports
Output: 8 CATV/G.hn RF ports
Console port: RS232 (RJ45)
G.x-S211G.hn coax slave:
Input: 1 CATV/G.hn RF port
Data output: 1*GE RJ45
CATV output: 1 RF port
Power consumption: <3w
G.x-M104G.now phone line master:
Data input: 2*GE SFP slots
Monitor Port: 1*GE SFP slot
Phone input: 4 phone input ports
Output: 4 phone and data Combo ports
Console port: RS232(RJ45) 
G.x-M108G.now phone line master:
Data input: 2*GE SFP slots
Monitor Port: 1*GE SFP slot
Phone input: 8 phone input ports
Output: 8 phone and data Combo ports
Console Port: RS232(RJ45) 
G.x-M124Data input: 2*GE SFP slots or 2*GE RJ45
Phone input: 24 phone input ports (RJ21)
Output: 24 phone and data Combo ports (RJ45)
Console port: RS232(RJ45) 
G.x-S111Input Port: 1* RJ11
Data output: 1*GE RJ45
Phone output: 1*RJ11
G.x-S104WInput Port: 1*RJ11
Data output: 4*10/100BaseT
WiFi: IEEE802.11b/g/n, 300Mbps

G.x solution equipment projects case 2: rooms TV application

rooms (TVs) on a single coax

rooms (TVs) on a single coax

  “We will primarily be coax for the installs. I do need some clarification on the amount of slaves and how it is calculated for each unit. The FOT M204 has 4 outputs and each output can support up to how many slaves?”

  • G.hn/RF Out put 1 > Slaves 1-8, 1-16, 1-32,1-64
  • G.hn/RF Out put 2> Slaves 1-8, 1-16, 1-32,1-64
  • G.hn/RF Out put 3> Slaves 1-8, 1-16, 1-32,1-64
  • G.hn/RF Out put 4 > Slaves 1-8, 1-16, 1-32,1-64

  I see in the diagram there is a NMS do you have network management software for the devices? or does this just indicate this is the network management port?

Solution and equipment needed:

  • 1) Each output port in master can connect max 16pcs slave.
  • 2) It’s managememt port, snmp management. FOT offering simple, easy-used web management configuration system.

Q: What is the impact to the throughput for the user device?
A: Each output in master throughtput is about 700M, if you connect less users, then each user could have more throughput.

Q: What is the Maximum I can combine on a single coax before performance is impacted?
A: Max 16pcs slave each output port/ each single coax.
Q: How are the slaves linked to the output if multiple outputs are combined on the same coax?
A: Generally, we use splitter to splitter 1 outputs for several slave, never use combiner.

Ask for FOT G.x series solution Details!

Latest Blog

About Us

Why FTTH can save telecom cost

FTTH: saving money

【Our Goal】

Benefits our customers via Fiber Network (FTTH).