Outline Dimension:

  The power supply size L:78 * W:28 * H:64mm

Power adapter (Telecom) outline dimension

Power adapter (Telecom) outline dimension

DC cable and plug’s Dimension:

  DC cable: 0.20mm2, VW-1, 80 ℃,300V DC plug: 5.5 * 2.1 * 9mm. Length: 1.5m

Input Characteristics:

  • Input voltage:
    Nominal voltage: 100-240Vac
    Variation Range: 90-264Vac
  • Input Frequency:
    Nominal Frequency: 50/60HZ
    Variation Frequency: 47/63Hz
  • Input Current:
    0.3Arms max (≤0.3Arms) at any input voltage and rated output voltage and rated load
  • Inrush Current:
    20Amps Max ((≤20Amps) at any input voltage and rated output voltage and rated load.

Output Characteristics:

  • Rated Output Voltage Current:
    Measurement mode: CR mode The unit total output power,under steady state conditions,shall not exceed 6.0W 
    Output#Normal Voltageminimum loadMax.Load
    +12Vdc10mA500mA
  • Rated Output Voltage 
    Output VoltageNormal VoltageMin. VoltageMax.VoltageTolerance
    +12Vdc11.4Vdc12.6Vdc±5%
  • Ripple and Noise:
    The ripple and noise are as follows when measure with Max. Bandwidth of 20mHz and parallel 47uF/0.1uF, crossed connected at testing point.
    Voltage     Ripple And Noise (Max.)
    +12Vdc        120mvp-p
  • Turn On Delay Time:
    1 second Max. (≤1S) at 100Vac input and output Max. Load.
  • Rise Time:
    20mS Max. (≤20mS) at100Vac input and output Max. Load.
  • Hold UP Time:
    10mS Min.at 100Vac input and output Max. Load.
  • Efficiency:
    72% Min.(≥72%) at 100Vac input and output Max. Load.
    75% Min.(≥75%) at 220Vac input and output Max. Load.

Output protection requirement:

  • Short Circuit Protection:
    The power supply will be auto recovered when short circuit faults remove.
  • Over current protection
    110% ~ 170% over current fault addition, the power automatically resume normal work.

    FOT FTTH Optical Receiver Package

    FOT FTTH Optical Receiver Package

Enviromental requirement

  • Operating Temperature: -10℃ to 40℃, (Full load Normal operation)
    Storage Temperature: -20℃ to 70℃
    Relative Humidity: 5%(0℃) ~ 95%(45℃)RH ,72Hrs, Full load ,Normal operating.
  • Vibration:
    Operating: IEC721-3-33M3
    5~9Hz,A=1.5mm
    9~200Hz,Acceleration 5m/s2
  • Transportation
    IEC721-3-2 2M2
    5-9Hz,A=3.5mm
    9~200Hz, Acceleration 5m/s2
    200~500Hz, Acceleration 15m/s2
  • Axial vibration,10 cycles per axis
    NO permanent damage may occur during testing
    The product has to restore to its original situation after power off/on.

Safety Requirement

  • Diel Ectrlc Strength (Hi-pot):
    Primary to secondary: 3000Vac/10mA/3S
  • Leakage current
    0.5mA maximum, at normal AC input voltage and frequency
  • Lighting Test
    EN55024: 1998 +A1: 2002+A2: 2003,EN61000-4-5: 2001 Differential model stand: 2KV

Ask for FTTH Catalogue & PON Solution!

Latest Blog

About Us

Why FTTH can save telecom cost

FTTH: saving money

【Our Goal】

Benefits our customers via Fiber Network (FTTH).

【FOT Telecom】

Your reliable fiber network equipment and service provider: Read More

Contact us

Email: sales@fiberoptictel.com fiberoptictelecom@gmail.com SKYPE: fanny-lee2007 SKYPE: fiberoptictelecom Tel: +86-20-22098370
Add.: Jitang Industrial Zone, No.8 Nanyun Five road, Huangpu, Guangzhou. 510663
ContactUs.com